Corbec is a Canadian leader in the field of hot-dip galvanizing, with several facilities in Québec. The company plays a key role in the corrosion protection of infrastructure components and steel structures for industrial, institutional, and transportation projects.

The mandate was to investigate a cracking problem appearing on certain welded assemblies after the galvanization process at Corbec. The objective was to understand the causes of the phenomenon to identify areas for improvement that could be applied in production.

Mandate

The deliverables provided by LDV include:

Finite element analysis of thermomechanical stresses induced by galvanization;

Comparison of different cases according to thickness, assembly types, and cooling methods;

Literature review and validation of hypothesis with physical tests;

Development and coordination of physical tests to confirm the FEA (Finite Element Analysis) results;

Practical recommendations for adapting designs, cooling methods, and manufacturing processes.

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful. More information on our Policies

Strictly Necessary Cookies

Cette option doit être activée à tout moment afin que nous puissions enregistrer vos préférences pour les réglages de cookie.

Show details
Analytics

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages.

Keeping this cookie enabled helps us to improve our website.